MAXIMIZE YOUR RESULTS WITH TIME, LABOR & COST SAVINGS
For Small to Mid-Size Applications & Automation Projects
Vision 430™ Programmable Logic Controller
MAIN APPLICATIONS:
- Dryers control
- Trimmers control
- Sorted machines control
- Super critical CO2
- Close loop extraction
- Hydrocarbon (Propane / Butane)
- Ampoules Filling
- Packaging Sorting control
- Weight automation
- Bagging automation
Vision™ - Rugged and Compact
Main Features:
Expandable up to 512 I/Os, LoadCell for weight measurement, Remote access & Web Server, Alarms via Email & SMS, variety of communication interfaces & protocols, Recipe management, Color HMI screens and more.
Advanced PLC Controller with incredible HMI Touchscreen Overview
- PLC
- HMI
- COMMUNICATION
- I\O
- Auto-tune PID, up to 24 independent loops
- Recipe programs and data logging via data tables
- Micro SD card – log, backup, clone & more
- Function Blocks
- High quality touchscreen
- Multi-language display
- Built-in Alarm Screens
- Mini USB for programming
- RS485/RS232
- 2 ports may be added: 1 Serial/Ethernet/Profibus and 1 CANbus
-
Protocols:
- MODBUS TCP
- SNMP V1
- CANopen, CANlayer2, UniCAN
- BACnet, KNX and M-Bus via gateway
- FB Protocol: for any 3rd party protocol
-
General Features:
- Web server, E-mail & SMS, Remote access utilities, 3G Modem support
- Expand up to 512 I/Os
- I/O options include digital, analog, high-speed, temperature & weight measurement
Visilogic™ Software for Vision430™
All-in-One programming environment. Simple, fast development for both Ladder and HMI applications.
- Develop your PLC and HMI applications in one environment
- Configure hardware & communications
- Establish modem and data communications
- Test and debug your programs
- Software Utilities Suite: remote access and data management tools
Product Details
Vision430™ | |
---|---|
I/O Expansion | |
Local or Remote I/Os may be added via expansion port or via CANbus. Expand up to 512 I/Os — see table below I/O Expansion Modules | |
Program | |
Application Memory | Application Logic: 1MB • Images: 12MB • Fonts: 512K |
Scan Time | 15µ sec per 1K of typical application |
Memory Operands | 8192 coils, 4096 registers, 512 long integers (32-bit), 256 double words (32-bit unsigned), 64 floats, 384 timers (32-bit), 32 counters Additional non-retainable operands: 1024 X-bits, 512 X-integers, 256 X-long integers, 64 X-double words |
Data Tables | 120K dynamic RAM data (recipe parameters, datalogs, etc.), up to 256K fixed data |
SD Card (Micro) | Store data logs, Alarm History, Data Tables, Trend data, export to Excel • Back up Ladder, HMI & OS, clone PLCs |
Enhanced Features | Trends: graph any value and display on HMI • String Library: instantly switch HMI language |
Operator Panel |
|
Type & colors | TFT LCD • 65,536 colors, 16 bit resolution • Brightness- Adjustable via touchscreen or software |
Display | Resolution: 480×272 pixels • Size: 4.3” |
Touchscreen | Resistive, Analog |
Keys | 5 programmable keys. Labeling options— function keys, arrows or customized |
General | |
Power Supply | 24VDC, except for V430-35-B1, which is 12/24VDC |
Battery | 7 years typical at 25°C, battery back-up for all memory sections and RTC |
Clock | Real-time clock functions (date and time) |
Environment | IP66/IP65/NEMA4X (when panel mounted) |
Standard | CE, UL Many of our products are also UL Class 1 Div 2 and GOST certified – please contact Unitronics |
Vision430™ models - Onboard I/Os
Inputs 1 | Outputs | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Article | Summary | Digital2 | HSC/Shaft-encoder2 | Analog | Temperature Measurement | Transistor 3 | PWM/HSO 3 | Relay | Analog | Operating Voltage |
V430-J-B1 | No onboard I/Os | None | None | None | None | None | None | None | None | 12/24VDC |
V430-J-RH2 | 10 Digital, 2 D/A Inputs1 6 Relay Outputs | 12 | 3 200kHz , 32-bit | 2 0-10V, 0-20mA, 4-20mA 10-bit | None | None | None | 6 | None | 24VDC |
V430-J-R34 | 20 Digital, 2 D/A Inputs1 12 Relay Outputs | 22 | 3 30kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA 10-bit | None | None | None | 12 | None | 24VDC |
V430-J-TR34 | 20 Digital, 2 D/A Inputs1 8 Relay, 4 High-speed Transistor Outputs | 22 | 3 200kHz , 32-bit | 2 0-10V, 0-20mA, 4-20mA 10-bit | None | 4 npn | 4 (3 PTO) 200 kHz max | 8 | None | 24VDC |
V430-J-RH6 | 6 Digital, 2 D/A1, 4 Analog Inputs 6 Relay Outputs | 8 | 1 200kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA and 4 0-20mA, 4-20mA 10-bit | None | None | None | 6 | None | 24VDC |
V430-J-RA22 | 8 Digital, 2 D/A, 2 TC/PT100/Digital1 Inputs 8 Relay, 2 Analog Outputs | 12 | 1 30kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA 14-bit | 2 Thermocouple, PT100 | None | None | 8 | 2 0-10V, 4 -20mA 12-bit | 24VDC |
V430-J-TRA22 | 8 Digital, 2 D/A, 2 TC/PT100/Digital1 Inputs 4 Relay, 2 Analog, 4 High-Speed Transistor Outputs | 12 | 1 200kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA 14-bit | 2 Thermocouple, PT100 | 4 npn | 4 (2 PTO) 200 kHz max | 4 | 2 0-10V, 4 -20mA 12-bit | 24VDC |
V430-J-T2 | 10 Digital, 2 D/A Inputs1 12 Transistor Outputs | 12 | 3 30kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA 10-bit | None | 12 pnp | 7 0.5kHz | None | None | 24VDC |
V430-J-T38 | 20 Digital, 2 D/A Inputs1, 16 Transistor Outputs | 22 | 2 30kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA 10-bit | None | 16 pnp | 7 0.5kHz | None | None | 24VDC |
V430-J-TA24 | 8 Digital, 2 D/A, 2 TC/PT100/Digital1 Inputs 10 Transistor, 2 Analog Outputs | 12 | 1 30kHz, 32-bit | 2 0-10V, 0-20mA, 4-20mA 14-bit | 2 Thermocouple, PT100 | 10 pnp | 5 0.5kHz | None | 2 0-10V, 4 -20mA 12-bit | 24VDC |
*Notes:
- In some models certain inputs are adaptable via wiring and software settings, and can function as digital,high-speed, analog, and in certain models as TC or PT100.
Adapting requires input pins. This reduces the number of digital inputs. Pin requirements:
• Each high-speed requires 1 or 2 pins according to high-speed mode.
• Each analog input requires 1 pin.
• Each TC requires 2 pins per TC input
• The first PT input requires 3 pins, and two additional pins for each additional PT input.
Example: V430-J-RA22 offers 12 digital inputs. Implementing 2 TC inputs requires 4 pins, leaving 8 pins free. Implementing 2 PT inputs uses 5 input pins. - The total number of digital inputs listed includes high-speed and adaptable inputs.
- The total number of digital outputs listed includes high-speed outputs.
*This page provides a general overview of Unitronics products.
For more details, please check the complete technical specifications for each product, located at the end of the page.
I/O Expansion Modules
Inputs | Outputs | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Expansion Modules | Digital 5 | HSC 5 | Analog | Temperature Measurement | Weight Measurement | Transistor6 | PWM/HSO 6 | Relay | Analog | Operating Voltage |
|
Digital | IO-DI8-TO8 | 8 pnp/npn | 1 5kHz 16-bit | None | None | None | 8 pnp | None | None | None | 24VDC 9 |
IO-DI8-RO4 | 8 pnp/npn | 1 5kHz 16-bit | None | None | None | None | None | 4 | None | 24VDC 9 | |
IO-DI8-RO8 | 8 pnp/npn | 1 5kHz 16-bit | None | None | None | None | None | 8 | None | 24VDC 9 | |
EX90-DI8-RO8 3 | 8 pnp | 1 5kHz 16-bit | None | None | None | None | None | 8 | None | 24VDC | |
IO-DI16 | 16 pnp/npn | 1 5kHz 16-bit | None | None | None | None | None | None | None | 24VDC 9 | |
IO-TO16 | None | None | None | None | None | 16 pnp | None | None | None | 24VDC | |
IO-RO8 | None | None | None | None | None | None | None | 8 | None | 24VDC 9 | |
IO-RO16 | None | None | None | None | None | None | None | 16 | None | 24VDC 9 | |
IO-DI8ACH | 8 AC | None | None | None | None | None | None | None | None | 110/220 VAC | |
Analog, Temperature and Weight/Strain Measurements | IO-AI4-AO2 | None | None | 4 0-10V, 0-20mA, 4-20mA 12-bit | None | None | None | None | None | 2 ±10V 12-bit+sign, 0-20mA, 4-20mA 12-bit | 24VDC |
IO-PT400 | None | None | None | 4 PT100/NI100/NI120 | None | None | None | None | None | Not relevant | |
IO-PT4K | None | None | None | 4 PT1000/NI1000 | None | None | None | None | None | Not relevant | |
IO-AO6X | None | None | None | None | None | None | None | None | 6 (Isolated) 0-10V, 0-20mA, 4-20mA 12-bit | 24VDC | |
IO-LC1 | 1 pnp | None | None | None | 1 Loadcell / Strain gauge | 2 pnp | None | None | None | 24VDC | |
IO-LC3 | 1 pnp | None | None | None | 3 Loadcell / Strain gauge | 2 pnp | None | None | None | 24VDC | |
IO-ATC8 | None | None | 8 Thermocouple, 0-10V, 0-20mA, 4-20mA 14-bit | None | None | None | None | None | Not relevant | ||
IO-AI8 | None | None | 8 0-10V, 0-20mA, 4-20mA 14-bit | None | None | None | None | None | None | Not relevant | |
XL Digital/Analog | IO-D16A3-RO16 | 16 pnp/npn | 2 30kHz 16/32-bit 8 | 3 0-20mA, 4-20mA 10-bit | None | None | None | None | 16 | None | 24VDC |
IO-D16A3-TO16 | 16 pnp/npn | 1 30kHz 16/32-bit 8 | 3 0-20mA, 4-20mA 10-bit | None | None | 15 pnp, 1 pnp/npn | 1 pnp 0.5kHz npn 50kHz | None | None | 24VDC | |
EX-D16A3-RO87 | 16 pnp/npn | 2 30kHz 16/32-bit 8 | 3 0-20mA, 4-20mA 10-bit | None | None | None | None | 8 | None | 24VDC | |
EX-D16A3-TO167 | 16 pnp/npn | 1 30kHz 16/32-bit 8 | 3 0-20mA, 4-20mA 10-bit | None | None | 15 pnp 1 pnp/npn | 1 pnp 0.5kHz npn 50kHz | None | None | 24VDC | |
High-speed Remote I/O Module | EXF-RC15 2,4 ,10 | 9 pnp/npn | 3 200kHz 32-bit | None | None | None | 4 npn | 4 (up to 3 PTO) | 2 | None | 24VDC |
*Notes
- Number of supported I/Os & I/O modules varies according to module
- The EXF-RC15 functions as a node in a Vision UniCAN network and connects to the Vision controller via CANbus and programmed in VisiLogic. The EXF-RC15 cannot be extended as regular I/O unit.
- The EX90 is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; Expansion adapter not required.
- Supported by Vision series. Not supported by M91 series.
- The total number of digital inputs listed includes high-speed inputs.. Example: the IO-D16A3-TO16 offers a total of 16 pnp/npn inputs. You can configure I4 as a HSC and I5 as a Counter reset; this reduces the available number of digital inputs to 14.
- The total number of digital outputs listed includes high-speed outputs. Example: the IO-D16A3-TO16 offers a total of 16 transistor outputs. You can configure 1 to High-speed output, reducing the number of available digital outputs to 15.
- Functions as local adapter. Can support up to 7 I/O modules
- 16-bit or 32-bit, depending on the PLC
- Also available as 12VDC – contact us for part number
*This page provides a general overview of Unitronics products.
For more details, please check the complete technical specifications for each product, located at the end of the page.
DOCUMENT DOWNLOAD
INSTALLATION GUIDE
TECHNICAL SPECIFICATIONS
2D DRAWINGS
File Name
2D Drawings
Download
3D DRAWINGS
File Name
3D Drawings
Download
Ubermorgen Innovations Gmbh:
“For me, most important is that I forgot that it is there - and it does its job, a very important job, controlling steam production for our factory.”
Coating Systems:
“We have found Unitronics to be one of those companies which inspire you to push the boundaries, we are reinventing a control system that has been around for many years on different platforms but with Unitronics we actively look to see how we can improve the product using the available technology but without it adding additional cost for our customers.”
Mar Cor Purification:
“The development process went a lot smoother due to the operator interface and PLC as one, and being programmed as one simultaneously…There are no annoying hurdles to jump, no additional communications software, communications hardware, or support costs. There is no burdensome software over protection getting in the way—just layout a design and build away!"
Timbersoft:
“The most cost effective and reliable way to fill the entry level PLC/HMI/SCADA bracket in the market.”
Aqua Interma Engineering:
“Among all automation the devices I work with, Unitronics is my favorite.”
AquaRD:
“With a friendly development environment and unrivaled quality to price ratio, Unitronics PLC’s are the perfect solution – we highly recommend them!”
Imapsa Automation:
"With fast delivery times, and constantly updated software, Unitronics has always listened to our customers many requests, and have implemented them since we decided to start our automation division in 2001. Great support via both the technical support team and the Unitronics forum. And, of course, great price!"
Greenmove Technologies:
“The Unistream offers the right balance between functionality and simplicity and is therefore an ideal fit for our application. With the Unistream we succeed in running our ‘mini-factories’ at the locations of our customers.”
Previous slide
Next slide